Manual sequencing
To run this function: Choose Design > Ring design > Charging > Manual sequencing, or...
Delay
The delay to be allocated to all holes you select. The value must correspond to one of the available detonators.
Complete the SELECT DELAY from and choose Apply to select the current delay. The following prompt will be displayed:
Select the hole of interest
Select a hole to which the current delay is to be allocated. The selected hole delay will be updated. If the delay or sequence attribute is currently being displayed for each hole (see Display Hole Delay or Display Hole Sequence), then the displayed value is also updated.
The prompt continues to be displayed in order for you to select all of the holes which are to be allocated the specified delay. Choosing Cancel redisplays the SELECT DELAY form so that a new delay can be specified for further manual sequencing.