Sequence clockwise
To run this function: Choose Design > Ring design > Charging > Sequence clockwise, or...
Indicate the First Hole. Press (ESC) to quit
Select the hole to be allocated the first delay time. A new prompt is displayed:
Indicate the Last Hole. Press (ESC) to quit
Select the last hole to be allocated a delay time.
Starting from the first selected hole and moving in an clockwise direction around the drive from which the holes are drilled, each hole lying between the selected holes is allocated a delay from the list of available detonators.
If the number of holes to be sequenced is greater than the number of delays available, the excess holes are given the longest delay available.
Warnings
The selected holes were not drilled from the same opening
The first and second holes selected were drilled from different openings. This function can only sequence delays of holes drilled from a single opening.
The hole selected is not editable with this function
The hole selected is not attached to one of the openings currently loaded. This function can only sequence delays of holes drilled from a currently loaded opening.
The point selected was not situated on a hole
The point selected is not on a Ring Design hole.